RSMAG

Electromagnetic flowmeter

Flow measurement for conductive liquids

Dn from 15 to 200 mm

Connections DIN 11851 and CLAMP DIN 32676

Measurement accuracy: ± 0.2%; ± 0.5%

PFA coatings

Power supply 85 ÷ 265Vac;12Vdc;24Vdc;24Vac

Datalogger on USB pendrive

Removable O-LED display module

Remote control via Smartphone

SKU 0537fb40a68c Categories ,

Description

RSmag flowmeters are suitable for applications in food and pharmaceutical industries. DIN or Clamp ISO 2852 process connection are suitable for applications with milk, beer or other drinks. Manufactured completely in stainless steel with the option for PFA lining makes RSmag suitable for pharmaceutical application.

Additional information

Flow rate range

Bidirectional on fluids with speeds up
to 10m / s

Range dimension / lining material

PFA DN25 ÷ DN250

Sensor pipe material

SS304

Housing material

epoxy painted aluminum

Electrodes material

SS316L – Hastelloy C – Titanio – Tantalio

Measure range

<0,1m3/h ÷ >600m3/h

Accuracy

±0,5% standard; ±0,2% opt

Repeatability

±0,1%

Fluid conductivity

>5μS/cm

Power supply

85÷265Vac, 24Vdc, 12Vdc.

Consumption

6W, max. 8W.

Temperature range

Remote version operating temperature: RUBBER -10 ÷ +80°C; PTFE -40 ÷ +150°C
Compact version operating temperature: RUBBER -10 ÷ +80°C; PTFE -40 ÷ +100°C
Storage temperature: -40÷85°C

Communication

modbus or Hart (opt.)

Data Logger

Internal data logger to USB pen drive for flow measurements and analog inputs storing; the measurement storage interval can be set from 15 to 3600 seconds

Output

4÷20mA: 0÷500Ω
Frequency output: 0,1÷10000 Hz
Pulse output: 24Vdc galvanically isolated or open collector galvanically isolated 24V 20mA (opt)
Alarm output: 2 relays, 3A 230Vac N.O.

Input signals

RSmag has 2 active analog inputs at 24Vdc for 2-wire transmitters connection (eg. Temperature or pressure) and 1 digital input for an external contact connection for the integrated batch function restart and for partial totalizer management.

Reverse Flow

Allows measure and totalization of reverse flow

Output Testing

Relays output: Transmitter can switch relays at testing value. Current Source:
Transmitter can be commanded to supply a specified test current between 4.0 and 20.0 mA. Frequency Source: Transmitter can be commanded to supply a specified test frequency between 1 and 10000 Hz.

Low Flow Cutoff

Adjustable. Below selected value, instantaneous flow and outputs are driven to the zero flow rate signal level

Humidity Limits

0-100% RH to 150 °F (65 °C), not condensing.

Damping

Adjustable between 1 and 99 seconds

Compact version IP rating

IP67

Remote version IP rating

sensor IP67 / IP68 (by request) –
converter IP67

Anti-condensation filter

Anti-condensation filter installed on converter

Operating Manual

Download

Data Sheet

Download

Related Product

get in touch

Write Us a Message

office hours

Monday – Friday
08:30 – 12:30
13:30 – 18:00

warehouse hours

Monday – Friday
08:00 – 12:30
13:30 – 17:00