PTU51

Ultrasonic level transmitter

Range 0.3 ÷ 6 meters

Blind zone 30 cm

IP67|68

Suitable for measuring of liquids

MODBUS RTU/BLUETOOTH comm. protocol

Power supply 24 Vdc

Output: 4 ÷ 20 mA analogue output

Remote control via Smartphone

Description

Non-intrusive level measurement systems are the preferred technology for many applications and for this reason SGMLEKTRA developed the level/distance transmitters PTU51. These units are compact with a unique simplicity of commissioning. Calibration and transmitter configuration is possible, even remotely, thanks to a MODBUS RTU connection together with the related software for the PC, or via VLW90M / VLW60T; Bluetooth display unit. The IP67|68 transmitter protection allows installation in underground wells.
The application for configuration and programming via bluetooth, available on Google Play, is compatible with the most commen devices with operating system ANDROID 4.2 and subsequents. it is possible to read the measurements detected by the transmitter and set the configuration parameters of the sensor. The smartphone terminal must be equipped with the BLUETOOTH device of class 1 and version 2.1. The maximum reception / transmission distance is 15m in open air.

Installation examples

Ptu51 Es b PTU51 First rain tank

– Applications where level measurement is of fundamental importance
– IP68 protection suitable to withstand conditions of prolonged immersion


Ptu51 Es a PTU51 Closed tank

– Suitable for measurements on even viscous and chemically aggressive liquids
– Applications where continuous measurement of the product level is required


Ptu51 Es c PTU51 Open tank

– Typically used for level measurement in shallow tanks containing water
– Suitable for measurements in purification plants

Additional information

Housing material

PP

Mechanical installation

1”GAS M – PP flange DN100 opt.

Protection degree

IP67, 68

Electrical connection

IP67 male connector with 5/10/15/20m
linking cable

Working temperature

-20 ÷ +60°C

Pressure

From 0,5 to 1,5 bar (absolute)

Power supply

20÷30Vdc

Power consumption

1.5W

Analog output

4÷20mA max 750ohm

Digital communication

MODBUS RTU

Range

0.3÷6m
In case of non perfectly reflecting surfaces, the maximum distance value will be reduced

Temperature compensation

digital in the working temperature

Accuracy

±0,2% (of the measured distance) not better than ±3mm

Resolution

1mm

Calibration

VLW90M / VLW60T prog. module; MODBUS; or via smartphone

Warm-up

30 minuts

Display

LCD display on VLW90M; VLW60T; VLW602; Android App (opt.)

Operating Manual

Download

Data Sheet

Download

Related Product

get in touch

Write Us a Message

office hours

Monday – Friday
08:30 – 12:30
13:30 – 18:00

warehouse hours

Monday – Friday
08:00 – 12:30
13:30 – 17:00