METER

METER

Ultrasonic level transmitter

Range 0,25 ÷ 6 m / 0,4 ÷ 10 m

IP67 mechanical protection

Suitable for liquids and solids

MODBUS RTU comm. protocol

Power supply 20÷30Vdc; 12 Vdc

Output 4 ÷ 20 mA (2 wire version); 4 ÷ 20 mA + 2 relays set (4 wire version)

ATEX

Remote control via Smartphone

Description

The METER ultrasonic level transmitters have 3 modes for configuration and calibration:

  1. by means of the configuration module VL601 which can be switched on and off on the METER (VL601 module is equipped with large LCD matrix display).
  2. via MODBUS RTU by PC interface with USB/RS485 and communication software 010F105A
  3. via smartphone Android App (only 4 wires version).

TThe non-contact technology makes it ideal for installations where it is necessary to minimize the maintenance costs. The removable display module allows its use as a fixed display or calibration module. Are available versions with 2-wire or 4-wire, 2-wire with communication HART and ATEX certification, 4-wire with communication MODBUS and 2 relays.

Installation examples

Meter Es a METERClosed tank

– Applications where continuous level measurement is required
– Suitable for measurements on even viscous and chemically aggressive liquids
– Atex certified versions for use in EX classified areas


Meter Es c METER

Basin

– Typically used for continuous level measurement in tanks containing water
– Particularly suitable for measurements in purification plants
– Possible installation in lifting or pumping stations


Meter Es b METER

Silos and hoppers

– Where required, the measurement of the level of granulated products, pallets and plastic chips
– Suitable for food processes
– Useful for measuring aggregates, sands etc.
– Suitable in plastic molding processes

Additional information

Housing/sensor material

PC or Al / PP wetted part (only PVDF for ATEX certified vers.)

Mechanical installation

2” GAS M (PP flange DN80 opt.)

IP rating

IP67 / IP68 (sensor)

Electrical connection

Internal push connectors

Working temperature

-20 ÷ +60°C

Pressure

From 0,5 to 1,5 bar (absolute)

Power supply

20÷30Vdc | 11÷14Vdc

Power consumption

0,6W (2-wires) – 1,5W (4-wires)

Analog output

4÷20mA, max 750ohm

Relays output

(4-wire only) n°2 3A 230Vac (n.o.)

Digital communication

MODBUS RTU for 4-wire vers. ; (opt.) HART for 2-wire vers.

Max measure range

max 0.25 ÷ 6m max 0.40 ÷10m (In case of non perfectly reflecting surfaces, the maximum distance value will be reduced)

Blind distance

0,25m (6m versions) / 0,40m (10m versions)

Temperature compensation

digital from -30 to 80°C

Accuracy

±0,2% (of the measured distance) not better than ±3mm

Resolution

1mm

Calibration

4 buttons or via HART / MODBUS RTU / BLUETOOTH

Thermal stabilization

5 minutes typical

Display

VL602 (opt.) plug-in display/keyboard 4 buttons matrix LCD

Ex-proof

ATEX II 1/2G Ex ia/db IIC T4 Ga/Gb ; II 1D Ex ta IIIC T135°C Da Tamb: -20 +60°C

Operating Manual

Download

Atex safety instructions

Download

Data Sheet

Download